Wednesday, January 25, 2012

High Performance Adsorption Chromatography



High-Performance Adsorption Chromatography: Here the analyte species (components 
to be analysed) are adsorbed onto the surface of a polar packing. The stationary phase 
consists of finely divided solid particles packed inside a steel tube. If the component mixture 
is eluted through this tube with the mobile phase, different components present in the mixture 
adsorb to different degrees of strength and they become separated as the mobile phase moves 
steadily through the column. The nature of the  adsorption involves the interaction of polar 
molecules with a very polar solid stationary phase. The stationary phase could be silica gel or 
alumina. This method is extensively used for the separations of relatively non-polar, water-
insoluble organic compounds (since polar molecules will be adsorbed on to the column 
momentarily). 


One particular application is in resolving isomeric mixtures such as meta- and 
para-substituted benzene derivatives.  




liquid chromatography LC / HPLC

LIQUID CHROMATOGRAPHY (LC/HPLC)  
Principle:  Early liquid chromatography  was carried out in long glass columns with wide 
diameter. The diameters of the stacked particles inside the column were of the order of 150- 
200 microns range. Even then, the flow rates (eluent time) of the mobile phase with the 
analyte were very slow and separation times were long - often several hours!. With the 
advent of latest technology the  particle diameters were reduced as small as to 10 microns 
with replacement of glass columns with steel ones. The flow rate of the mobile phase was 
improved by applying high pressure to the column using pumps and hence the performance 
was improved. This development led the  instrument to be mostly called as  “High-
Performance Liquid  Chromatography” or  “High-Pressure Liquid Chromatography” 
(HPLC). Though HPLC retains major of the credits to the analytical side, the earlier one of 
simple Liquid Chromatography still finds applications in the preparative purposes.  

The HPLC technique can be divided into four main categories depending on the nature of the 
processes that occur at the columns as follow:

High-Performance Adsorption Chromatography: Here the analyte species (components
to be analysed) are adsorbed onto the surface of a polar packing. The stationary phase
consists of finely divided solid particles packed inside a steel tube. If the component mixture
is eluted through this tube with the mobile phase, different components present in the mixture
adsorb to different degrees of strength and they become separated as the mobile phase moves
steadily through the column. The nature of the  adsorption involves the interaction of polar
molecules with a very polar solid stationary phase. The stationary phase could be silica gel or
alumina. This method is extensively used for the separations of relatively non-polar, water-
insoluble organic compounds (since polar molecules will be adsorbed on to the column
momentarily). One particular application is in resolving isomeric mixtures such as meta- and
para-substituted benzene derivatives.

 High-Performance Partition Chromatography:  It is the most widely used liquid
chromatographic procedures to separate most kinds of organic molecules. Here the
components present in the analyte mixture distribute (or partition) themselves between the
mobile phase and stationary phase as the  mobile phase moves through the column. The
stationary phase actually consists of a thin liquid film either adsorbed or chemically bonded
to the surface of finely divided solid particles. Of these the latter is considered more
important and has a distinct stability advantage. It is not removed from the solid phase either
by reaction or by heat and hence it is more popular. It finds wide applications in various
fields, viz., pharmaceuticals, bio-chemicals, food products, industrial chemicals, pollutants,
forensic chemistry, clinical medicine, etc.

High-Performance Ion-Exchange Chromatography:  This method is used to separate
mixtures of ions (organic or inorganic),  and finds its application mostly in protein
separations. The stationary phase consists of very small polymer resin “beads” which have
many ionic bonding sites on their surface, termed as Ion Exchange Resins. This resin can be
either an anion exchange resin, which possesses positively charged sites to attract negative
ions, or a cation exchange resin, which possesses negatively charge sites to attract positive
ions. If the analyte mixture which contains mixture of ions is introduced into the column
packed with suitable ion-exchange resin, selected ions will be attached or bonded on to the
resin, thus being separated from other species that do not bond. Later, these attached ions can
be dislodged from the column by repeated elution with a solution that contains an ion that
competes for the charged groups on the resin surface, in other words, which has high affinity
for the charged sites on the resin than the analyte ions. Thus the analyte ions get exchanged
and separated from the column.

High Performance Size Exclusion Chromatography:  This technique is for separating
dissolved species on the basis of their size and particularly applicable to high-molecular-
weight species like oligomers and polymers to determine their  relative sizes and molecular
weight distributions. Here, the stationary phase is polymer resin, which contains small pores.
If the components to be separated are passed through the column the small sized particles can
easily enter into these pores and their mobility is retarded. Whereas the large sized particles,
which can’t enter into these pores can come out of the column fast and elude first. Thus the
separation of various sized particles is possible  through variations in the elution time. It is
classified into two categories based on the nature of the columns and their packing as:


Gel Filtration Chromatography - which uses hydrophilic packing  to separate polar species
and uses mostly aqueous mobile phases. This  technique is mostly used to identify the
molecular weights of large sized proteins & bio-molecules.

Gel Permeation Chromatography -  which uses hydrophobic packing to separate nonpolar
species and uses nonpolar organic solvents. This technique is used to identify the molecular
weights of polymers.

Instrumentation:  The basic HPLC system consists of  a solvent (mobile phase) reservoir,
pump, degasser, injection device, column and  detector. The pump draws the mobile phase
from the reservoir and pumps it to the column through the injector. At the end of the column
(effluent end), a detector is positioned. Mostly UV absorption detector is used. In the case of
analytical studies, after the detection the eluents are collected in waste bottles. In the case of
preparative studies the eluents are fractionally collected for further studies. Most of the
HPLC design will be the same as described for all the four main groups previously described.
However, there can be differences in selecting the specific detectors for particular type of
analysis, say for example, with ion-exchange chromatography, detectors commonly used are
conductivity detectors for obvious reasons. Other important detectors for HPLC separations
include refractive index detector, fluorescence  detector and mass selective detector. The
following is the most generalised outlay of the HPLC system:





Disadvantages:  Column performance is very sensitive, which depends on the method of
packing. Further, no universal and sensitive detection system is available.



ANALYSIS THROUGH CHROMATOGRAPHY

ANALYSIS THROUGH CHROMATOGRAPHY 

The technique through which the chemical components present in complex mixtures are 
separated, identified and determined is termed as chromatography. This technique is widely 
used like spectroscopy and is a very powerful tool not only for analytical methods but also 
for preparative methods. Compounds of high grade purity can be obtained by this method. 
Chromatography can be simply defined as follows: 

“It is the technique in which the components of a mixture are separated based upon the 
rates at which they are carried or moved through a stationary phase (column) by a gaseous 
or liquid mobile phase”.  


Based on the mobile phase this technique can be simply classified into two categories as: 
Liquid Chromatography and Gas Chromatography.  The column which holds the stationary 
phase (which in the form of small particles of the diameter of the order in microns), plays 
unique role in these processes. Usually silica is the base material for producing this phase.

Monday, January 23, 2012

Electron Spin Resonance Spectroscopy ESR

Electron Spin Resonance Spectroscopy (ESR):
The basic principle of electron spin resonance spectroscopy is  that, electrons always have a
spin and thus have a magnetic moment. Thus, the magnetic resonance theory applies to
electrons too like that of nuclei, as in NMR. Especially this technique is of high value when it
comes to the compounds which contain odd electrons, i.e. those substances which have
paramagnetic behaviour (if electrons are paired as in bonded  orbital then their mutual
spinning will cancel each other and there will be no response for the applied magnetic field,




whereas, if it is unpaired then it can align with the applied magnetic field and the feasibility 
of getting ESR spectra is higher). Thus, the  principle and the instrumentation are much 
similar to that of NMR technique. It is also referred as,  Electron Magnetic Resonance 
(EMR) or Electron Paramagnetic Resonance (EPR) spectroscopy. 

It is mostly used as a potential technique to study the formation and lifetime of free radicals, 
which are the major intermediates in most of the organic reactions. Another important 
application is in the estimation of trace amounts of paramagnetic ions, particularly in 
biological works like, Mn2+, Mg2+  etc. 

Nuclear Magnetic Resonance Spectroscopy NMR

Nuclear Magnetic Resonance Spectroscopy (NMR) : 
Principle :  In NMR substances absorb energy in the radio frequency region of the electro-
magnetic spectrum under influence of a strong magnetic field. It is a well known fact that the 
nuclei of the atoms bonded to each other in molecules spin on an axis like a top. Since nuclei 
are positively charged, this spin will create a  small magnetic field. If an external magnetic 
field is applied to these nuclei this magnetic  field will split into two energy levels. The 
energy difference is very small and corresponds to radiofrequency energy which is unique for 
every molecule and will give the information regarding the nature of the compounds and the 
presence of various functional groups and their environment.  

Since this technique is mostly measures the spinning of the hydrogen nuclei (almost all the 
organic compounds contain hydrogen atoms!), it is sometimes referred as Proton Magnetic 
Resonance (PMR) spectroscopy. 

Instrumentation :  The instrumentation for this technique includes powerful magnet, radio-
frequency signal generator, amplifier, detector, etc. The following is the outline of the 
instrument: 



Applications :  The application lies mostly in the identification and structural analysis of 
organic compounds and thus, it is mostly a tool for qualitative  analysis.  It gives valuable 
information regarding the position of the functional groups in a molecule and provides 
distinguished spectra for the isomer. Much  precise information on the structure of the 
compounds can be obtained using the same technique with other magnetic nuclei like C 13
, 
O17
, the instrumentation being the same except that the sweep of the magnetic field is varied. 
  
Disadvantages: Very expensive and the instrumentation is complex and needs exceptional 
skills to operate. Its sensitivity ranges from moderate to poor, however, can get clear 
information using C13
 or O17 
NMR. The usage of the solvents  is limited and in most of the 
situations deuterated solvents are required. 

Microwave Spectroscopy

Microwave Spectroscopy : 
This technique is actually an extension to IR spectroscopy. Microwave region lies at the far 
infra-red region of the electromagnetic spectrum and its absorption by molecules give rise to  
change in the  rotational energies  of the molecules. 

In IR spectroscopy, the molecules are subjected to changes in vibrational energies; the energy required for making changes at rotational levels is lesser than that for vibrational levels. Though the principles are same to 
that of IR, the instrumentation is slightly different and it requires samples in gaseous state for 
the analysis. 



Its applications are limited to smaller and simpler molecules since larger 
molecules will have interactions between the rotational energy levels within the molecule 
through various bonds they have. Besides qualitative analysis, this technique can be applied for conformational analysis  of simpler compounds (study of stereo chemistry of the compounds).